RF Meter Accessories
Attenuator DG20
Extend the Maximum Power of your RF Meter – Increase the RF measurement range by 100x or 20 dB – Compatible with: Standard Log-Per antenna of the HF32D, HF35C and the HF38B.
Increase the signal strength measuring range of your RF Meter with the DG20 Attenuator (100x High Frequency Signal Reducer)
If your RF Meter measurement range is set to maximum and the display indicates (“1…”) this attenuator will allow the HF-Analyzer (HF Analyser) to accurately display higher signal strength measurements and extend the range of your RF Meter.
Adding the DG20 to your RF measurement arsenal will:
Extends the measuring range of the RF Meters
Allows for 20dB or 100x higher field strength measurements in the frequency range of 10 MHz – 3 GHz
How it Works:
- Attach the DG20 attenuator to a compatible RF Analyzer (RF Analyser)
- Attach the LogPer directional antenna to the DG20
- Power on the RF Analyzers (RF Analysers) and configure appropriately
- Hold the RF Analyzer with an outstretched arm
- The analyzer will display the intensity of RF radiation on its LCD display
- Simply multiply the measured value by 100 to obtain the actual value
Compatible with: HF32D, HF35C and the HF38B
Attenuator DG20_G10
Increase the Maximum Power Range of your RF Analyzer (RF Analyser) by 20 dB or 100x – Designed for: Standard Log-Per antenna and the UBB27 antenna of the HFE35C,HFW35C, HF58B, HF58B-r, HF59B, HFE59B, HFW59D
Extend the measuring power of your RF Meter with the DG20_G10 Attenuator (20 dB or 100x High Frequency Signal Reducer)
If your RF Meter indicates a (“1…) on the far left of the LCD display, and measurement range is set to maximum, you are measuring a signal over the maximum signal strength of the RF Meter. The DG20_G10 attenuator will allow the RF Meter to display the higher signal strength measurements with accuracy and raise the measurement range of your RF Meter.
Adding the DG20_G10 to your tool kit will:
- Allows for 100x higher field strength measurements and raise the measuring range of the RF Meters by a factor of 20 dB
- High Field strength reduction power of 20 dB (100x) in the frequency range of 10 MHz – 10 GHz
How it Works:
- Connect the DG20_G10 RF attenuator to a compatible RF Meter
- Attach the UBB27 multi-directional antenna or LogPer directional the to the DG20_G10
- Turn on the RF Analyzer and set up appropriately
- Scan the area and hold the RF Analyzer with your arm extended
- RF radiation power density will be displayed on the LCD display
- Multiply the displayed value by 100x to obtain the true value
- When using the HF59B or the HFE59B, power level adapter switches can be configured to automatically display the actual value
Compatible with: HFE35C,HFW35C, HF58B, HF58B-r, HF59B, HFE59B
EMF / RF Meter Case CC2
Ensure your RF Meters, RF Detectors , RF Analyzer / RF Analysers and Equipment are Protected During Transport. Add a Hard Plastic Carrying Case Compatible with: HF32D, HF35C RF Meter by Gigahertz Solutions and the Acoustimer AM-10.
Protect your RF Meter (RF Analyzer / RF Analysers) or Your EMF Meter Investment with a Rigid Hard cover Plastic Carrying Case.
Interior Dimensions – L x W x H (11.5″ x 8″ x 2.5″) (29 cm x 20 cm x 6.4 cm)
EMF / RF Meter Case K2
This hard cover plastic case is larger than the K5 Carrying Case and will hold any 2 Gigahertz Solutions RF or EMF Meters and protect them during transport.
Protect your Gigahertz Solutions Meters with a rigid hard cover plastic carrying case
Dimensions – L x W x H (13″ x 10.6″ x 7″) (33 cm x 27 cm x 18 cm)
EMF / RF Meter Case K5
This hard cover plastic case will hold up to 2 Gigahertz Solutions Meters and will help protect your meters during transport. It can be used for any of the Gigahertz Solutions EMF Meters as well as the HF32D, HF35C, HFW35C, and HFW59D RF Meters.
Protect your Gigahertz Solutions Meters with a rigid hard cover plastic carrying case
Dimensions – L x W x H (13″ x 10.6″ x 3.2″) (33 cm x 27 cm x 8 cm)
EMF / RF Meter Case K6
This hard cover plastic case is the largest case available and has 6 slots for various meters and accessories. This case is included with the MK70-3D professional test kit but it works with any combination of Gigahertz Solutions Meters.
Protect your Gigahertz Solutions Meters with a rigid hard cover plastic carrying case
Dimensions – L x W x H (17.7″ x 14.2″ x 5.6″) (45 cm x 36 cm x 14 cm)
Weight – 3.5 Lbs (1.6kg)
High Pass Filter – HP700_G3
This High Pass Filter will Remove Signals Below 700 MHz from the Measurement Spectrum and Aid with Source Identification – Compatible with: Standard Log-Per antenna and the UBB27 antenna of the HFE35C
Increase the Source Identification Capabilities of your RF Analyzer with the HP800_G3 High Pass Filter
The growth and constant upgrade of wireless products and services has made source identification during RF environmental assessments increasingly difficult.
Adding the HP700_G3 to your RF measurement equipmentl will:
- Suppresses lower frequency disturbances when high frequency analysis is required
- Effectively Suppress signals of amateur radio, radio and TV transmission signals which allows for isolation of RF emissions from cellular tower transmissions and other higher frequency RF radiation
- Will isolate signals between 700 MHz – 3 GHz in the RF Spectrum
- Effectively cuts off signals in the band of 10 MHz – 600 MHz
How it Works:
1) Attach the HP700_G3 filter to a compatible RF Analyzer (RF Analyser)
2) Attach the LogPer directional antenna or the UBB27 multi-directional antenna to the HP700_G3
3) Power on the RF Analyzer and configure appropriately
4) Hold the RF Analyzer with an outstretched arm
5) The analyzer will display the intensity of RF radiation on its LCD display
6) As the filter causes 1 dB of signal loss, multiply the reading on the display by 1.25
Compatible with: HFE35C, HF59B, HFE59B
Know for sure what RF levels you are being exposed to…
High Pass Filter – HP800_G3
This High Pass Filter will Remove Signals Below 800 MHz from the Measurement Spectrum and Aid with Source Identification – Compatible with: Standard Log-Per antenna and the UBB27 antenna of the HFE35C.
Increase the Source Identification Capabilities of your RF Analyzer with the HP800_G3 High Pass Filter
The growth and constant upgrade of wireless products and services has made source identification during RF environmental assessments increasingly difficult.
Adding the HP800_G3 to your RF measurement equipmentl will:
- Suppresses lower frequency disturbances when high frequency analysis is required
- Effectively Suppress signals of amateur radio, radio and TV transmission signals which allows for isolation of RF emissions from cellular tower transmissions and other higher frequency RF radiation
- Will isolate signals between 800 MHz – 3 GHz in the RF Spectrum
- Effectively cuts off signals in the band of 10 MHz – 600 MHz
How it Works:
- Attach the HP800_G3 filter to a compatible RF Analyzer (RF Analyser)
- Attach the LogPer directional antenna or the UBB27 multi-directional antenna to the HP800_G3
- Power on the RF Analyzer and configure appropriately
- Hold the RF Analyzer with an outstretched arm
- The analyzer will display the intensity of RF radiation on its LCD display
- As the filter causes 1 dB of signal loss, multiply the reading on the display by 1.25
Compatible with: HFE35C, HF59B, HFE59B
Preamplifier – HV10_27G3
Amplifies Weaker Signals by 10x and Aids with Source Identification – Compatible with: Standard Log-Per antenna or the UBB27 antenna of the HFE35C, HF58B, HF58B-r, HF59B, HFE59B RF Meters.
Increase the sensitivity of your RF Meter with the HV10_27G3 Preamplifier (Amplification factor of 15dB (10x))
If your RF Meter measurement range is set to its finest range and you are suspicious of the presence of a weaker signal, this preamplifier allows the RF Analyzer to accurately display the weaker signal strength measurement.
Adding the HV10_27G3 to your RF measurement equipment will:
- Pinpoint small field strength signals which are below the lower field strength limit of the RF Meter
- Extend the sensitivity of your RF Meter by 10 times in the frequency range of 27 MHz – 3 GHz
- Allow for field strength measurement of RF signals which are off the low end scale of the RF Meter
How it Works:
- Attach the HV10_27G3 Preamplifier to a compatible RF Analyzer (RF Analyser)
- Attach the LogPer directional antenna or the UBB27 multi-directional antenna to the HV10_27G3
- Power on the RF Analyzer and configure appropriately
- Hold the RF Analyzer with an outstretched arm
- The analyzer will display the intensity of RF radiation on its LCD display
- Simply divide the displayed value by 10 to obtain the actual value
- If using the HF59B or the HFE59B, power level adapter switches can be configured to automatically display the actual value
Compatible with: HFE35C, HF58B, HF58B-r, HF59B, HFE59B
Preamplifier – HV20_2400G10
Having issues finding a low-frequency source? The HV20_2400G10 is a little unit with a huge impact. It boosts sensitivity of RF Analyzers enabling you to precisely capture weaker field-strength signals.
Adding the HV20_2400G10 to your RF measurement equipment will:
- Analyze RF field strength signals which would normally be below the limit of your RF Analyzer
- Increase the measurement sensitivity of a RF Analyzer by 100x (20dB) in the frequency range of 2400 MHz – 10 GHz
How it Works:
- Attach the HV20_2400G10 preamplifier to the appropriate RF Meter
- Attach the LogPer directional antenna to the HV20_2400G10
- Configure the unit for measurement and power on
- Scan the area of concern by holding the RF Meter with an extended arm
- The meter will indicate the power density of RF radiation on its digital display
Divide the measured value by 100 to obtain the exact value
Compatible with: HFW35C and HFW59D
Protective Cover – RFCover1
Protect your RF Measuring Equipment with a Flexible soft cover – Works with All RF Detectors (RF Meters or RF Analyzers / RF Analysers): HF32D, HF35C, HFE35C, HF38B, HFW35C, HF59B, HFE59B, HFW59D, HFEW59D (Black in Colour / Color)
Safeguard your RF Measuring Equipment Investment – Add a Protective Cover to your RF Tool Kit
The Protective Cover will:
- Custom fit any Gigahertz Solutions RF Analyzer, RF Analyser, RF Detector
- Improve handling and grip
- Protects your RF Analyzer from bumps, minor drops and rough handling
Made From Silicone
- Available in black for the HF – RF Meter Series
- Supplied with the HFE59B but optional for all other HF Series Meters
UBB2410 – Omni Antenna
Explore 360 degree RF Measurements from 2.4 GHz to 10 GHz with this Omni-Directional Antenna – Compatible with RF Analyzers: HFW35C and HFW59D.
Eliminate the Guess Work with Directional RF Measurement
The 3D Ultra Broadband Omni-Directional UBB2410 Antenna assimilates and reads Total RF exposure conditions typical for a human body. Every measurement delivers a 360º RF snap shot
Additionally, adding the UBB2410 to your RF Meter will:
- Provide an extended frequency analysis range of 2.4GHz – 10GHz
- Eliminate measurement complications caused by indoor RF reflections
- Enable access to typically ‘hard to reach’ wireless hot spots
- Measure sources including: Radar, Bluetooth, WLAN, WiMAX and cordless telephones
Compatible with:
HFW35C, HFW59D
UBB27 – Omni Antenna
Explore 360 degrees RF Measurements from 27 MHz to 3.3 GHzwith this Omni-Directional Antenna – Compatible with RF Analyzers (RF Analyser): HFE35C, HF59B, HFE59B
Eliminate Guess Work with 3 Dimensional RF Measurement Capability
The UBB27 Ultra Broadband Omni-Directional Antenna assimilates and reads Total RF exposure conditions typical for a human body. Every measurement delivers a 360º RF snap shot of RF.
In addition, adding the UBB27 to your measurement arsenal will:
- Provide an extended frequency analysis range of 27MHz – 3.3 + GHz
- Eliminate measurement complications caused by indoor RF reflections
- Enable access to typically ‘hard to reach’ wireless hot spots
- Measure sources including: CB-radio and other amateur frequencies, broadcasting TV (analogue and digital), mobiles (GSM, UMTS, 3G, 4G, LTE), cordless phones (CT1+ and DECT), radar and WLAN – will somewhat monitor frequencies up to 6 GHz
- Indicator lights that verify connectivity and functionality
Compatible with: HFE35C, HF59B, HFE59B
USB Data Logger
USB data logger stick for recording the DC output of our measuring devices. The logger includes simple to use software which creates a graphical output of the logged values. Compatible with the HF58B, HF59B, HFE59B, HFW59D RF Analyzers.
Record the data output of your HFE59B RF Analyzer with our USB Data Logger
- DC-voltage data logger
- Suitable for use with the HF58B, HF59B, HFE59B, HFW59D
- To be connected to the HFE59B with customized USB Cable which is included with the product
- Data logger output can be exported to Excel for further analysis
- Logging rate is adjustable from 1s to 12 hours
- Stores 32000 measured values, DC voltage ranging from 0 to 30V